You have picked out a new stove. Maybe it replaces a tired one on the same hearth, maybe it goes into an open fireplace that never heated the room, maybe you are switching from wood to pellets. Before it goes in, the chimney it will vent into gets a camera inspection. Crockett Chimney Solutions does this on every stove install we take on in Mission Viejo, and we recommend it to anyone buying a stove from somebody else too. This post explains why, what it costs and what it can turn up.
Why a new stove calls for a camera
NFPA 211, the standard most chimney work in this country follows, describes inspections at three depths. The lightest is a look at what is open to view. The middle one, Level 2, is what it asks for when something about the chimney's use changes, and putting in a different appliance is exactly that kind of change. A new stove burns at different temperatures, needs a different flue size and may vent in a different way from what was there before. The flue that suited the old appliance may not suit the new one.
So the question is not whether the old flue was fine. It is whether it is fine for what you are about to put under it.
What we look for on the camera
With us a Level 2 is $380. For that, we:
- run a camera from the firebox or the stove collar to the top of the flue and record it;
- look at each visible tile joint and any metal liner for cracks, gaps, offsets and corrosion;
- check for heat damage or glazing left from an old chimney fire;
- measure the flue so it can be matched against what the new stove's maker calls for;
- look at the smoke chamber, the damper area and the connection point the new stove will use;
- check the chimney where it is reachable from the attic and outside, along with the crown and cap;
- write it up with stills from the video and a plain note on each finding.
You keep the recording and the write-up. If the stove dealer, a permit inspector or your insurer wants proof the flue was checked, you have it.
What it tends to turn up
Most of these inspections before a stove swap end with one of four results:
- The flue is sound and the right size. The install goes ahead as planned.
- The flue is sound but too big. Common when a stove goes into an old masonry fireplace. A large clay flue over a small modern stove draws poorly and builds up creosote fast. A stainless liner sized to the stove fixes this, and most insert and stove installs include one anyway.
- The tile is cracked or the joints are open. A liner can usually run down through it. Some chimneys need repair above the roof first.
- There is old fire damage. Glazed, cracked or bulging tile means a chimney fire at some point in its life. We show you where and talk through the options before anything else happens.
The inspection against the cost of the job
People sometimes balk at a $380 inspection before an install. We see it as a small share of what a stove and liner cost, and the one point where a problem in the flue costs nothing but information. Find a cracked tile after the stove and liner are in, and you are paying to take them back out.
If the flue has years of buildup in it, a sweep comes before the camera so we can see the tile, from $405. If the chimney needs a new cap, it is quoted on site.
Booking the camera before your install
Let us know what stove you are buying (make and model, or at least whether it burns wood, pellets or gas), where it will go and what sits there now. Send those details here. We set a time for the Level 2 and, if you want us to do the install too, give you one written quote covering the liner, the stove hookup and any chimney work the camera found, line by line.
Older chimneys in Mission Viejo
Much of Mission Viejo was built from the late 1960s on, so many of its masonry chimneys have decades of heat, settling and Southern California shaking behind them. Even modest movement over the years can open hairline cracks in flue tile that you cannot see from the hearth. A crack like that matters little to an open fireplace used twice a year. Under a stove that runs every evening, it lets heat and gases reach the framing around the chimney. The camera is how we find it.
Factory-built fireplaces
Many homes in south Orange County have metal, factory-built fireplaces rather than masonry. Those come with a tested chimney system, and only certain stoves and inserts are listed to go into them. Part of a Level 2 on one of those is reading the label plate and confirming what the maker allows. Sometimes the answer is that a stove cannot go in without changing the chimney, and you want to know that before you buy.
After the install
Once the new stove is running, the next check is a yearly one. A Level 1 at $160 suits a stove that is burned the way it was the winter before. Pair it with a sweep and you have a dated record each year of what the flue looks like.
If a new stove is in your plans this season, tell us what you are buying through our contact page and we will book the camera first.
Would You Rather We Looked at It?
Reading helps, but a stove shows its wear up close. Crockett Chimney Solutions works out of Mission Viejo on wood stoves, pellet stoves and the flues above them, and every repair is priced in writing before we start.